loa-bao-dong-va-den-al105nx-alarm-horn-sounder-xenon-strobe-beacon-e2s-vietnam.png
Eac-logo Culs-approval Vds-approval Ce-approval Gost-approval Med-approval
2-31-120

AL105NX Alarm Horn Sounder & Xenon Strobe Beacon

The AL105NX features the 112dB(A) A105N alarm horn sounder combined with the L101X Xenon strobe beacon. The compact, robust housing is ideal for all general signalling applications including fire, security and process control.

The 5 Joule Xenon strobe generates over 200 candela of light output. DC versions have multile flash rates selectable udring installation. Sounder & beacon may be connected from a single supply for simultaneous operation or from separate supplies for independent operation.

Specification

 
Sounder:
Maximum output: 112dB(A) @ 1 metre [103dB(A) @ 10ft/3m]
Nominal output: 105dB(A) @ 1m +/- 3dB - Tone 2 [96dB(A) @ 10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: 3
Volume control: Max. 105dB(A); Min. 96dB(A) - Tone 2
Effective range: 60m/197ft @ 1KHz
Stage switching: Negative - Reverse polarity stage switching on DC units.
Beacon:
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
Peak Candela: 500,000 cd - calculated from energy (J)
Effective Intensity: 250 cd - calculated from energy (J)
Peak Candela: 86,935 cd* - measured ref. to I.E.S.
Effective Intensity: 200 cd* - measured ref. to I.E.S.
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Tube life: Emissions are reduced to 70% after 5 million flashes
General:
Voltages DC: 24V dc (10-30V dc); 48V dc (35-60V dc)
  [DC units can use 24V ac for single stage applications.]
Voltages AC: 24V ac; 115V ac; 230V ac
Ingress protection: IP66
Housing material: High impact UL94 V0 & 5VA FR ABS
Colour: Red (RAL3000), grey (RAL7038) & white.
Cable entries: 2 x M20 clearance gland entries in side & back
Terminals: 0.5 to 1.5mm² cables.
Operating temp: -25 to +55°C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: DC: 0.95kg/2.1Ibs AC:1.20kg/2.64Ibs
*Candela measurements representative of performance with clear lens at optimum voltage.
*SPL data +/-3dB(A). Measured at optimum voltage.

Part Codes

Version: Part code:
12V dc AL105NXDC012[x]/[y]
24V dc AL105NXDC024[x]/[y]
48V dc AL105NXDC048[x]/[y]
24V ac AL105NXAC024[x]/[y]
115V ac AL105NXAC115[x]/[y]
230V ac AL105NXAC230[x]/[y]
[x] = Housing colour: G: Grey, R: Red, W: White
[|y] = Lens colour: A: Amber, B: Blue, C: Clear,
G: Green, M: Magenta,
R: Red, Y: Yellow
Suffix part number with ‘-P’ for programmable, 4 stage, 45 tone version (not available with UL approval).
Suffix part number with ‘-F’ for forward facing Xenon beacon.
Note: Standard beacon configuration is downward facing.
Suffix part number with ‘-UL’ for UL approved version.
Suffix part number with ‘-M’ for MED approved version [24V dc unit, Clear lens only]
CPR - EN54-3 & EN54-23:
Part codes: AL105NXDC024[x]/C-F, AL105NXDC048[x]/C-F
Environmental class: Type B - for outdoor use
Visual range: Category W-2.4-4.8 (24V dc)
Category W-2.5-5.0 (48V dc)
Signal colour: Clear (1Hz)

Alarm sounder

Version: Voltage: Current :
12V dc 10-30V dc 25mA*
24V dc 10-30V dc 25mA*
48V dc 35-60V dc 50mA*
24V ac 50/60Hz +/-10% 40mA
115V ac 50/60Hz +/-10% 20mA
230V ac 50/60Hz +/-10% 15mA
* current at nominal voltage on Tone 2

Xenon beacon

Version: Voltage: Current:
12V dc   10-14V dc 500mA
24V dc   20-28V dc 250mA
48V dc   42-54V dc 175mA
24V ac 50/60Hz +/-10% 300mA
115V ac 50/60Hz +/-10% 70mA
230V ac 50/60Hz +/-10% 35mA

Tone Table

Stage 1 WAV file Frequency Description. (Stg 2 (Stg 3
T 1   340 Hz Continuous T 2 T 5
T 2   800/1000Hz @ 0.25 sec Alternating T 17 T 5
T 3   500/1200Hz @ 0.3Hz 0.5 sec Slow Whoop T 2 T 5
T 4   800/1000Hz @ 1Hz Sweeping T 6 T 5
T 5   2400Hz Continuous T 3 T 20
T 6   2400/2900Hz @ 7Hz Sweeping T 7 T 5
T 7   2400/2900Hz @ 1Hz Sweeping T 10 T 5
T 8   500/1200/500Hz @ 0.3Hz Sweeping T 2 T 5
T 9   1200/500Hz @ 1Hz - DIN / PFEER P.T.A.P. T 15 T 2
T 10   2400/2900Hz @ 2Hz Alternating T 7 T 5
T 11   1000Hz @ 1Hz Intermittent T 2 T 5
T 12   800/1000Hz @ 0.875Hz Alternating T 4 T 5
T 13   2400Hz @ 1Hz Intermittent T 15 T 5
T 14   800Hz 0.25sec on, 1 sec off Intermittent T 4 T 5
T 15   800Hz Continuous T 2 T 5
T 16   660Hz 150mS on, 150mS off Intermittent T 18 T 5
T 17   544Hz (100mS)/440Hz (400mS) - NF S 32-001 T 2 T 27
T 18   660Hz 1.8sec on, 1.8sec off Intermittent T 2 T 5
T 19   1.4KHz-1.6KHz 1s, 1.6KHz-1.4KHz 0.5s -NFC48-265 T 2 T 5
T 20   660Hz Continuous T 2 T 5
T 21   554Hz/440Hz @ 1Hz Alternating T 2 T 5
T 22   544Hz @ 0.875 sec. Intermittent T 2 T 5
T 23   800Hz @ 2Hz Intermittent T 6 T 5
T 24   800/1000Hz @ 50Hz Sweeping T 29 T 5
T 25   2400/2900Hz @ 50Hz Sweeping T 29 T 5
T 26   Bell T 2 T 15
T 27   554Hz Continuous T 26 T 5
T 28   440Hz Continuous T 2 T 5
T 29   800/1000Hz @ 7Hz Sweeping T 7 T 5
T 30   300Hz Continuous T 2 T 5
T 31   660/1200Hz @ 1Hz Sweeping T 26 T 5
T 32   Two T chime. T 26 T 15
Country specific or custom tone configurations and alarm frequencies are available upon request.