e2xl25f-ex-e2s-vietnam-loa-phong-thanh-25w-khong-tia-lua-pa-loudspeaker-25w.png
Ul Csfm Iecex-approval Atex-approval Culs-approval Ce-approval
1-32-040

E2xL25F PA Loudspeaker 25W

The hazardous area E2xL25F PA loudspeaker is UL/cULs approved for Class I Div 2 and Class II Div 2 as well as IECEx and ATEX certified for Zone 2 and 22 applications.

The E2xL25F is available with either a 70V or 100V line transformer or as a low impedance loudspeaker. 
The E2x range features enclosures manufactured from lightweight, corrosion proof PPS and high impact, fire retardant ABS re-entrant flare horns; both of which are suitable for the harshest of environments.

Specification

 
SPL: 111dB +/-3dB @ 1w @ 1m (Pink)
124dB +/-3dB @ 25w @ 1m (Rated)
Rated power: 25 Watts RMS
70v line tappings: 25w / 12.5w / 6w / 2w tappings
(z=196 Ohms / 392 Ohms /
816.67 Ohms / 2.45k Ohms)
100v line tappings: 25w / 12.5w / 6w / 2w tappings
(z=400 Ohms / 800 Ohms /
1.67k Ohms / 5k Ohms)
Low impedence: 8 Ohm or 16 Ohm
Dispersion: 130° @ 1kHz & 32° @ 4kHz
Frequency range: 300Hz to 8000 Hz
DC Line monitoring: 2.2µF Capacitor
(Transformer version)
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 PPS & ABS
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 - 2.5mm² (20-14 AWG)
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: Low impedance: 2.75kg/6.05Ibs
Transformer: 3.25kg/7.15Ibs
*SPL data +/-3dB(A). Measured at optimum voltage.

Part Codes

Part Code: Ident.: Description:
Product type: E2xL25
Horn type: F Flare Horn
Type: V100
V070
R008
R016
100V Line
70V Line
8 Ohm Low impedance
16 Ohm Low impedance
Cable entries: A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5
½” NPT & ½” NPT
Stopping plug material: N Nylon
Bracket: 1
2
304 (A2) Stainless Steel
316 (A4) Stainless Steel
Approvals: A1 UL, cULs, IECEx & ATEX
Enclosure: B Black
e.g: E2xL25FV100AN1A1B E2xL25 PA Loudspeaker with flare horn.
100V line transformer with one M20 cable entry and one 1/2"NPT entry.
Approved to IECEx,ATEX & UL.
Black enclosure.

Coding

  • IECEx / ATEX:
    II 3G Ex nA IIC T2 Gc Ta -20°C to +55°C
    II 3D Ex tc IIIC 85°C Dc Ta -20°C to +40°C
    II 3D Ex tc IIIC 100°C Dc Ta -20°C to +55°C
  • NEC Class / Zone ratings US:
    Class I Zone 2 AEx nA IIC T2 Gc Ta -20°C to +55°C
    Zone 22 AEx tc IIIC T85°C Dc Ta -20°C to +40°C
    Zone 22 AEx tc IIIC 100°C Dc Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Ex nA IIC T2 Gc Ta -20°C to +55°C
    Ex tc IIIC 85°C Dc Ta -20°C to +40°C
    Ex tc IIIC 100°C Dc Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I, Div 2, ABCD T2C Ta -20°C to +55°C
    Class I, Div 2, ABCD T2D Ta -20°C to +40°C
    Class II, Div 2, FG T5 Ta -20°C to +55°C
    Class II, Div 2, FG T6 Ta -20°C to +40°C
    Class III, Div 1&2 Ta -20°C to +55°C