Sounder: |
|
Maximum output: |
112dB(A)1m [103dB(A) 10ft/3m] |
Nominal output: |
105dB(A)1m +/-3dB Tone 2 {96dB(A) 10ft/3m] |
No. of tones: |
32 (UKOOA / PFEER compliant) |
No. of stages: |
Alarm horn:3, Xenon Beacon (DC only):2
Double strike pattern can be remotely switched |
Volume control: |
Max. 105dB(A); Min. 96dB(A) – Tone 2 |
Effective range: |
60m/197ft @ 1KHz |
Stage switching: |
Negative (Reverse polarity switching on DC units) |
Beacon: |
|
Energy: |
5 Joules (5Ws) |
Flash rate: |
1Hz (60 fpm)
DC units: Optionally 1.5Hz & double strike |
Synchronisation: |
1Hz flash rate automatically synchronised |
Peak Candela: |
500,000 cd – calculated from energy (J) |
Eff. Intensity cd: |
250 cd – calculated from energy (J) |
Peak Candela: |
49,788 cd* – measured ref. to I.E.S. |
Eff. Intensity cd: |
125 cd* – measured ref. to I.E.S. |
Tube life: |
70% emissions after 8 million flashes |
General: |
|
Voltages DC: |
24V dc (10-30V dc); 48V dc (35-60V dc)
[DC units can use 24V ac for single stage applications.] |
Voltages AC: |
24V ac; 115V ac; 230V ac |
Ingress protection: |
IP65 |
Enclosure material: |
High impact UL94 V0 & 5VA FR ABS |
Lens material: |
UV stable PC UL94 V0 FR
Bayonet lens fixing , Anti-tamper locking screw. |
Cable entries: |
2 x M20 clearance gland entries in side & back |
Terminals: |
0.5 to 1.5mm² cables. |
Operating temp: |
-25 to +55°C [-13° to +131°F] |
Storage temp: |
-40 to +70°C [-40° to +158°F] |
Relative humidity: |
90% at 20° [68°F] |
Weight: |
DC: 1.00kg/2.2Ibs AC:1.25kg/2.75Ibs |
Candela measurements representative of performance with clear lens at optimum voltage.
SPL data +/-3dB(A). Measured at optimum voltage. |