E2xBL2 Multi-function LED Beacon & Status Light

The hazardous location E2xBL2 LED beacon and status light is UL/cULs approved for Class I Div 2, Class II Div 2, Class I Zone 2/22 as well as IECEx and ATEX certified for Zone 2 and 22 applications.

The hazardous area E2xBL2 LED status light & beacon utilises an array of high power Cree® LED's, orientated to optimise visibility in any direction. The beacon can be configured as a steady beacon for status indicator use, with a light output of up to 87 candela. Alternatively one of the five flashing modes, with a light output of up to 160 candela, may be used for warning applications. DC voltage versions feature three remotely selectable stages enabling multiple warnings to be signalled from one device. The UV stable colour filter enhances the light output and is field replaceable.

Specification

 
Source: Array of 4 x High Power Cree® LED's
Modes: 1Hz flash (60 fpm)
1.5Hz flash (90 fpm)
2Hz flash (120 fpm)
Double strike flash
Triple strike flash
High Power Steady
Low Power Steady
Eff. Intensity cd: 87 cd - High Power Steady
Eff. Intensity cd: 160 cd - 1Hz flash
Lens colours: Amber, Blue, Clear, Green, Magenta, Red & Yellow
Voltages DC: 24V dc (18-54V dc)
Voltages AC: 115V ac; 230V ac
Ingress protection: IP rating per EN60079-0:IP64
IP rating per EN60529:IP66
Type rating per UL50E/NEMA250:4/4X/13
Enclosure material: UL94V0 PPS & ABS
Lens material: Borosilicate glass dome with PC prismatic lens cover.
Guard: Stainless Steel dome guard as standard
Cable entries: Dual M20x1.5 or 1/2"NPT
Terminals: 0.5 - 2.5mm² (20-14 AWG)
Line monitoring: Blocking diode included
EOL can be factory fitted
LED life: 60,000 hours
Operating temp: -20 to +55°C [-4° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20°C [68°F]
Weight: 1.48kg/3.25Ibs
* All candela data is representative of performance with clear lens at optimum voltage.

Current Consumption

Version: Voltage: Steady High Power
Current:
Steady Low Power
Current:
Flashing 1Hz
Current:
24V dc 18-54V dc 240mA 134mA 110mA
115V ac 103.5-126.5V ac 50/60Hz 95mA 78mA 90mA
230V ac 207-253V ac 50/60Hz 48mA 37mA 45mA

Part Codes

Part Code: Ident.: Description:
Product type: E2xBL2 LED Beacon/Status Light
Voltage: AC115
AC230
DC024
115V ac 50/60Hz
230V ac 50/60Hz
24V dc (18-54Vdc)
Cable entries: [e] A
B
C
M20x1.5 & ½” NPT
M20x1.5 & M20x1.5
½” NPT & ½” NPT
Stopping plug material: [m] N Nylon
Bracket & Guard: [s] 1
2
304 (A2) Stainless Steel
316 (A4) Stainless Steel
Version: [v] A1 UL, cULs, IECEx & ATEX
Enclosure: [x] B Black
Lens colour: [y] A, B, C
G, M, R
Y
Amber, Blue, Clear
Green, Magenta, Red
Yellow
e.g: E2xBL2DC024BN1A1B/R E2xBL2 LED Beacon in 24Vdc with dual M20 entries,
nylon stopping plug, UL, cULs, IECEx & ATEX approved
Black enclosure with Red lens
Also available as the E2xC1X05 combined alarm sounder and Xenon beacon and the
E2xC1LD2 combined alarm sounder and LED beacon.

Coding

  • ATEX / IECEx certification
    II 3G Ex nA IIC Gc T4 Ta -20°C to +55°C
    II 3D Ex tb IIIC Dc T85°C Ta -20°C to +55°C
  • NEC Class / Zone ratings US
    Class I Zone 2 AEx nA IIC Gc T4 Ta -20°C to +55°C
    AEx tb IIIC Dc T85°C Ta -20°C to +55°C
  • CEC Class / Zone ratings Canada
    Ex nA IIC Gc T4 Ta -20°C to +55°C
    Ex nA IIC Gc T4A Ta -20°C to +40°C
    Ex tb IIIC Dc T85°C Ta -20°C to +55°C
  • NEC & CEC Class / Division Ratings for US / Canada
    Class I, Div 2, ABCD T4A Ta -20°C to +55°C
    Class II, Div 2, FG T6 Ta -20°C to +55°C
    Class III, Div 1&2 Ta -20°C to +55°C

Multi-function patterns

Stage 1:
[On board]
Stage 2:
[Remote]
Stage 3:
[Remote]
 
Steady High Power Flashing 1Hz Triple Strike
Steady Low Power Flashing 1Hz Triple Strike
Flashing 1Hz 2x Flash 2Hz Triple Strike
Flashing 1.5Hz Flashing 2Hz Double Strike
Flashing 2Hz Triple Strike Triple Strike
Double Strike Steady High Power Triple Strike
Triple Strike Flashing 2Hz Double Strike
Note: Remote second and third stage on DC units only